Flow instrument portfolio- Endress + Hauser

Electromagnetic flow meters for all kind of volumetric flow metering such as liquid products, water, CIP solutions etc.

Vortex flows meters for steam, utility gases and non-conductive utility liquid media such as condense water.

Coriolis flow meters, (Mass flow meters), are used for metering of mass- and volume flow in liquid products and fluids without conductivity where high accuracy is essential. Coriolis flow meters can include density and brix metering.

Flow switches for liquids and CIP media.

Thermal mass flow meters are used for compressed air monitoring and total flow measurement of utility gases.

Product detail

  • Product code
    Endress + Hauser: Flowmeter, Electro-Magnetic
  • APPLICATIONS
    For processes in liquid products, water, CIP solutions, condense water, utility gases, liquid products and fluids without conductivity where high accuracy is essential.
 

Promag H 100

Application: All fluids with a minimum conductivity of > = 5 µS/cm can be measured: - beverages, e.g. fruit juice, beer, wine - milk products, fruit mixtures - salt solutions - acids and caustic solutions, etc. A minimum conductivity of > = 20 µS/cm is required for measuring demineralized water

Benefits

  • Very compact housing
  • M12 connection
  • 2 outputs in non-bus versions
  • PFA lining for cleaning temperatures up to +150 °C
  • Suitable for CIP/SIP cleaning and piggable
  • Sensor body in stainless steel for high sanitary safety
 

Promag H 300

Application: All fluids with a minimum conductivity of > = 5 µS/cm can be measured: - beverages, e.g. fruit juice, beer, wine - milk products, fruit mixtures - salt solutions - acids and caustic solutions, etc.

Benefits

  • PFA lining for cleaning temperatures up to +150 °C
  • Suitable for CIP/SIP cleaning and piggable
  • Sensor body in stainless steel for high sanitary safety
  • Field housing, IP 67, stainless steel
  • With Touch Control: Operation without opening the housing
 

Promag W 400

Application: Flowmeter for the water and waste water industry with a weight-optimized sensor. Suitable for applications in the water and waste water industry.

Benefits

  • Used together with the Liquiline CM44x transmitter series
  • Broad measurement range
  • Hygienic design certified by EHEDG and 3-A
  • Absolute loop safety thanks to Memosens and unique electrode connection surveillance
  • Sterilizable and autoclavable
 

Technical specifications

  • Product code
    Endress + Hauser: Flowmeter, Electro-Magnetic
  • APPLICATIONS
    For processes in liquid products, water, CIP solutions, condense water, utility gases, liquid products and fluids without conductivity where high accuracy is essential.
 

Chlorine - CCS142D

Application: Chloromax CCS142D is the digital, free chlorine sensor for all kinds of water

Benefits

  • Long calibration and maintenance intervals
  • Easy membrane replacement thanks to prefabricated membrane cap
  • Measured values are not affected by conductivity fluctuation
  • Sensor can be installed in flow cell CCA250 or in immersion assemblies. Measurement virtually independent of the flow at flow velocities above 30 l/h or ~8 gal/h (CCA250) or above 15 cm/s or ~0.5 ft/s (immersion)
  • Maximum process safety through no-contact inductive signal transmission
 
 

Nitrate - Viomax - CAS51D

Application: Viomax CAS51D measures nitrate or SAC in drinking water, process water and wastewater applications as well as the utilities sector. Organic load or nitrate in inlet and outlet Determination of CODeq or TOCeq Monitoring, control and optimization of treatment processes Nitrate monitoring in the aeration basin and denitrification stage

Benefits

  • Cost-effective - Easy, chemical-free handling is safe, environmentally friendly and saves on operational expenditure
  • Extremely fast response time - Measured value processing in the sensor provides reliable real-time process information
  • Fast and easy commissioning - Sensor comes precalibrated and preconfigured ex factory
  • Perfect adaption to open basins - Fast and flexible sensor positioning with Flexdip CYH112 holder and CYA112 assembly system

 

 

Turbidity - ITM-51

Application: Preferred turbidity meter for detection of phase separation like water/milk phase but also for products like cream and whey

Benefits

  • Compact front flush sensor
  • Temp range -10…130 °C (Up to 140 °C max. 120 min for CIP)
  • High reproducibility: ≤ 1 % of full scale 
  • Selectable output value (%TU, NTU, EBC)
  • Measurement range: 200…300.000 NTU equivalent
 

 

Related products

Tetra Pak supplies a range of flow measurment from Endress + Hauser.

 

Tetra Pak supplies a range of Flow switch from IFM.

 

Tetra Pak supplies a range of flow measurment from Endress + Hauser.

 

Tetra Pak supplies a range of flow measurment from Endress + Hauser.