Conductivity instrument portfolio- Endress + Hauser

In keeping with its comprehensive approach to plant components, Tetra Pak supplies an extensive range of measuring instruments. This is a specialist area that you can discuss in depth with us to ensure that we satisfy your process monitoring needs. Selected components from leading manufacturers

 

Product detail

  • Product code
    Endress + Hauser: Conductivity
  • APPLICATIONS
    For processes in treatment of industrial water and wastewater
 

LDL200, IO-Link - IFM

Application: The LDL200 is an, IO-Link plug&play, real-time temperature compensated conductivity sensor for measurement of conductivity in the food industry. To be used for product monitoring in dairies and the beverage industry, CIP system control, phase separation of product/water and product/product mixtures in pipe systems, alkali and acid concentration control, etc. If IO-Link is used then LDL200 can be used for both conductivity and temperature measurement.

Benefits

  • Measuring range 100 μS/cm to 1000 mS/cm
  • One 4-20 mA analogue output with IO-link
  • PEEK sensor – wetted part and SS integral housing
  • IP69K Protection – M12 Cable Connection
  • Measuring Accuracy 2 % or MW ± 25 μS/cm
  • IO-link plug & play commissioning (no display or push button)
  • Process temperature -25...100 C ; (< 1 h: 150) suitable for CIP and SIP
  • Repetability 1 % MW ± 25 μS/cm
  • With integrated temperature measurement sensor
 

CLD transmitters - CLD134

Application: Transmitter for measurement of conductivity and concentration with inductive sensor for the food industry, e.g. product monitoring in dairies and the beverage industry, CIP system control, phase separation of product/water and product/product mixtures in pipe systems, alkali and acid concentration control, etc.

Benefits

  • Transmitter housing made of stainless steel
  • Sensor made of highly resistant plastic (PEEK)
  • Sterilisable sensor
  • High measuring reliability due to extensive self-monitoring functions
  • Insensitive to polarisation and soiling
  • Sensor versions for all process connections used in hygienic applications
  • Large two-line display allows simultaneous display of measured value and temperature
  • Standard version extendable by function extension with remote measuring range switching
 

CLS82D

Application: The CLS82D is a conductivity meter used for utilities and in effluent applications including waste water (for example phase separation).

Benefits

  • Used together with the Liquiline CM44x transmitter series
  • Broad measurement range
  • Hygienic design certified by EHEDG and 3-A
  • Absolute loop safety thanks to Memosens and unique electrode connection surveillance
  • Sterilizable and autoclavable
 

CLD18

Benefits

  • EHEDG/3A approval
  • Durable
  • Temperature compensation response time (t90 < 50 s)
  • Cost effective
  • Compact

 

Technical specifications

  • Product code
    Endress + Hauser: Conductivity
  • APPLICATIONS
    For processes in treatment of industrial water and wastewater
 

Chlorine - CCS142D

Application: Chloromax CCS142D is the digital, free chlorine sensor for all kinds of water

Benefits

  • Long calibration and maintenance intervals
  • Easy membrane replacement thanks to prefabricated membrane cap
  • Measured values are not affected by conductivity fluctuation
  • Sensor can be installed in flow cell CCA250 or in immersion assemblies. Measurement virtually independent of the flow at flow velocities above 30 l/h or ~8 gal/h (CCA250) or above 15 cm/s or ~0.5 ft/s (immersion)
  • Maximum process safety through no-contact inductive signal transmission
 
 

Nitrate - Viomax - CAS51D

Application: Viomax CAS51D measures nitrate or SAC in drinking water, process water and wastewater applications as well as the utilities sector. Organic load or nitrate in inlet and outlet Determination of CODeq or TOCeq Monitoring, control and optimization of treatment processes Nitrate monitoring in the aeration basin and denitrification stage

Benefits

  • Cost-effective - Easy, chemical-free handling is safe, environmentally friendly and saves on operational expenditure
  • Extremely fast response time - Measured value processing in the sensor provides reliable real-time process information
  • Fast and easy commissioning - Sensor comes precalibrated and preconfigured ex factory
  • Perfect adaption to open basins - Fast and flexible sensor positioning with Flexdip CYH112 holder and CYA112 assembly system

 

 

Turbidity - ITM-51

Application: Preferred turbidity meter for detection of phase separation like water/milk phase but also for products like cream and whey

Benefits

  • Compact front flush sensor
  • Temp range -10…130 °C (Up to 140 °C max. 120 min for CIP)
  • High reproducibility: ≤ 1 % of full scale 
  • Selectable output value (%TU, NTU, EBC)
  • Measurement range: 200…300.000 NTU equivalent
 

 

Related products

Tetra Pak supplies a range of analyzers for pH- and conductivity measurment from Endress + Hauser.

Conductivity measurment mainly used for alkali and acid concentration control.Inline pH measurment in different products using glass-free sensors to optimise production control and product quality.